ISO EM 324

  • Lifting Area : 35 m2
  • Working Speed : 30 Rpm
  • Rate of Engine : 0,37 KW
  • Operating Voltage: 380 V
  • Miller diameter : 25,4mm
  • IP Protection Factor : IP54

ISO EM 524

  • Lifting Area : 40 m2
  • Working Speed : 24 Rpm
  • Rate of Engine : 0,50 KW
  • Operating Voltage: 400 V
  • Miller diameter : 25,4mm
  • IP Protection Factor : IP54
STA 1-10-24 KE

  • Miller diameter : 25,4mm
  • Output Torque : 100 N
  • Maximum Door Weight: 450 kg/ 35m2
  • Working Speed : 24Rpm
  • Rate of Engine : 0,37 KW
  • Operating Voltage: 400 V/3
  • Frequency : 50 Hz
  • Current Rate: 2A
  • Control Voltage : 24V
  • Transfer of the engine: s3-%60 ED
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP 65
STA 1-12-19 KE

  • Miller diameter : 25,4mm
  • Output Torque : 120 N
  • Maximum Door Weight: 750 kg/45 m2
  • Working Speed : 19Rpm
  • Rate of Engine : 0,55 KW
  • Operating Voltage: 400 V/3
  • Frequency : 50 Hz
  • Current Rate: 2A
  • Control Voltage : 24V
  • Transfer of the engine: s3-%60 ED
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP 54
STA 1-8-45 KE

  • Miller diameter : 25,4mm
  • Output Torque : 100 N
  • Maximum Door Weight: 450 kg/35 m2
  • Working Speed : 45Rpm
  • Rate of Engine : 0,55 KW
  • Operating Voltage: 400 V/3
  • Frequency : 50 Hz
  • Current Rate: 5.1A
  • Control Voltage : 24V
  • Transfer of the engine: s3-%60 ED
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP 65
STAC 1-10-24 KE

  • Miller diameter : 25,4mm
  • Output Torque : 100 N
  • Maximum Door Weight: 450 kg/35 m2
  • Working Speed : 24 Rpm
  • Rate of Engine : 0,37 KW
  • Operating Voltage: 400 V/3
  • Frequency : 50 Hz
  • Current Rate: 2A
  • Control Voltage : 24V
  • Transfer of the engine: s3-%60 ED
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP 65
STAC 4-4-24 KE

  • Miller diameter : 25,4mm
  • Output Torque : 40 N
  • Maximum Door Weight: 350 kg/16 m2
  • Working Speed : 24 Rpm
  • Rate of Engine : 0,37 KW
  • Operating Voltage: 400 V/3
  • Frequency : 50 Hz
  • Current Rate: 1.3A
  • Control Voltage : 24V
  • Transfer of the engine: s3-%60 ED
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP 65
NICE SD 100-24

  • Lifting Area : 35m2
  • Working Speed : 24Rpm
  • Rate of Engine : 0,35 KW
  • Operating Voltage: 400V/3
  • Frequency : 50 Hz
  • Current Rate: 2A
  • Control Voltage : 24V
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP54
NICE SD 140-20

  • Lifting Area : 45 m2
  • Working Speed : 20Rpm
  • Rate of Engine : 0,55 KW
  • Operating Voltage: 400V/3
  • Frequency : 50 Hz
  • Current Rate: 2.2A
  • Control Voltage : 24V
  • Operating Temperature : -20 / + 60degree
  • IP Protection Factor : IP54
 
GFA SE 9.24

  • Lifting Area : 35m2
  • Working Speed : 24Rpm
  • Rate of Engine : 0,37 KW
  • Operating Voltage: 400V/3
  • Frequency : 50 Hz
  • Current Rate: 2A
  • Control Voltage : 24V
  • Operating Temperature : -20 / + 60 degree
  • IP Protection Factor : IP65
GFA SE 14.21

  • Lifting Area : 45 m2
  • Working Speed : 24Rpm
  • Rate of Engine : 0,37 KW
  • Operating Voltage: 400V/3
  • Frequency : 50 Hz
  • Current Rate: 2.2A
  • Control Voltage : 24V
  • Operating Temperature : -20 / + 60degree
  • IP Protection Factor : IP65
 
BFT ARGO

  • Lifting Area : 20 m2
  • Working Speed : 30 Rpm
  • Rate of Engine : 70 W
  • Operating Voltage: 230 V
  • Frequency : 50 Hz
  • Current Rate: 1.6A
  • Control Voltage : 24V
  • Operating Temperature : -20 / + 55 degree
  • IP Protection Factor : IP40
BFT ARGO G

  • Lifting Area : 35 m2
  • Working Speed : 18 Rpm
  • Rate of Engine : 70 W
  • Operating Voltage: 230 V
  • Frequency : 50 Hz
  • Current Rate: 1.6A
  • Control Voltage : 24V
  • Operating Temperature : -20 / + 55 degree
  • IP Protection Factor : IP40